Quantcast
Channel: RAM | STAAD Forum - Recent Threads
Browsing all 23543 articles
Browse latest View live
ā†§

RE: RAM reinforcement chapter 7.3 eurocode

Dear Seth, Indeed it was a different version of the manual (8 in my case). What I donā€™t understand is which rule is following to add reinforcement when crack width is excessive. Does it add more bars...

View Article


RE: RAM reinforcement chapter 7.3 eurocode

The diameter of bars selected to meet the requirements of 7.3 are the same bar diameters specified for the design strip. Crack control is what Eurocode 2 section 7.3 is all about. It is only...

View Article


RAM Foundation - Overstrength Factor

California Building Code requires that foundation reinforcement must be designed using overstrength load combinations (section 1616.10.14). Ā When I include the overstrength combinations in the "Custom...

View Article

ram modeler - roof parapet wall

The building I am modeling has a slightly sloped (2 degree) roof with a 2.5' tall parapet wall on 3 sides.Ā  I thought it would be as simple as adding a wall on top of the roof and then simply changing...

View Article

PLATE SELECTION VIA OPEN STAAD

Dear All,I am not able to select Plates using OpenSTAAD.I have created group "aaaa" for for some plates.here is codeSub Main() Dim objOpenSTAAD As Object Dim aaaa As String Set objOpenSTAAD =...

View Article


How to validate STAAD.Pro Analysis Result by Hand Calculations IS 456 2000

I do know manual verification methods and want to know exactly how to validate and verify RCC Design by using IS 456 2000 code in STAAD.Pro V8i SS6 & details of method like matrix method or portal...

View Article

Help with structural analysis

Can anyone help with plastic analysis of beams and frames ? I am a student and severely struggling with my assignment. I have been reading text books and watching videos to no avail. Is there free...

View Article

RE: how to remove the warning ??????????????? and i m having high deflection...

The model that you have created has too many Instability warning messages. The "Member Tension" command you have used for all the hanging columns, is mainly responsible for this. These vertical members...

View Article


RE: how to remove the warning ??????????????? and i m having high deflection...

sir Actually I am trying to hang the building through these steel bars Could you please suggest for the model...........

View Article


RE: how to remove the warning ??????????????? and i m having high deflection...

If you want to keep those hanging columns as tension only members, then you need to release the moments (MY, MZ) at the start and end of the beams at the connection with the hanging columns. You need...

View Article

RE: how to remove the warning ??????????????? and i m having high deflection...

As cited correctly, the problem is with Tension only specification to those members. I would rather suggest them to model to carry axial forces only. Please refer to the attached model where 99%...

View Article

RE: how to remove the warning ??????????????? and i m having high deflection...

sir, Would you please suggest some tendons properties that i can use in my model to hang effectively

View Article

RE: staad error saying member design failed for some members

I would suggest you to use the latest version of STAAD.Pro V8i SS6 version 20.07.11.50. I have used SEISMIC 1 parameter and the program is providing correct output. Please refer to the attached...

View Article


RE: how to remove the warning ??????????????? and i m having high deflection...

STAAD.Pro doesn't suggest any type of tendons. You need use the tendons as per your project requirements.

View Article

RE: how to remove the warning ??????????????? and i m having high deflection...

i need to define??????????? please tell me propertiesof tendons which i can use to generate the new tendon material

View Article


how to remove the warning ??????????????? and i m having high deflection...

STAAD SPACESTART JOB INFORMATIONENGINEER DATE 06-Mar-16END JOB INFORMATIONINPUT WIDTH 79UNIT METER KNJOINT COORDINATES10 2.5 0 2.5; 11 13.5 0 2.5; 12 24.5 0 2.5; 13 35.5 0 2.5; 14 46.5 0 2.5;15 57.5 0...

View Article

RE: How to validate STAAD.Pro Analysis Result by Hand Calculations IS 456 2000

Are you trying to validate analysis results or design results?

View Article


RE: How to validate STAAD.Pro Analysis Result by Hand Calculations IS 456 2000

1st part is Analysis as we have to see all members pass and 2nd part is IS 456 2000 validation that is after design completion.So plz assist in validating Analysis and Design results both.

View Article

RE: direct analysis method using aisc360-10

The answer to your question can be found here: communities.bentley.com/.../19523.loads-factored-by-1-6-for-asd

View Article

direct analysis method using aisc360-10

when i design steel using direct analysis method the code requirements that i must factored the combinations including notional ladsĀ  by 1.6 my question does staad handle the 1.6 factors automatically...

View Article
Browsing all 23543 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>