RE: Design of Steel Ramp on ground

$
0
0

Dear sir,

Thanks a lot. 

As of now I have applied the foundation as per your post also divided the plates in parts as suggested.

1. My concern now is what is the the number of nodes that needed to be added or increased so as to model that the structure is resting on ground?

2. The beams in center (Beam no 51, 52 and single beam 32, 111, 110, 107, 108, 109) are also filled up with soil and compacted. Is there any supports to be added to it for stability?

Revised Staad file added.

Thanks in advance.(Please visit the site to view this file)


RE: Design of Steel Ramp on ground

$
0
0

Dear sir,

Thanks a lot. 

As of now I have applied the foundation as per your post also divided the plates in parts as suggested.

1. My concern now is what is the the number of nodes that needed to be added or increased so as to model that the structure is resting on ground?

2. The beams in center (Beam no 51, 52 and single beam 32, 111, 110, 107, 108, 109) are also filled up with soil and compacted. Is there any supports to be added to it for stability?

Revised Staad file added.

Thanks in advance.(Please visit the site to view this file)

RE: HOLLOW PIPE VS I BEAMS

$
0
0

(Please visit the site to view this file)

HOLLOW PIPE VS I BEAMS

$
0
0

Dear Everyone

Hereby I am attaching my model and i used hollow pipe of 165mm OD for my columns instead of ISMB 400.

And the same is not failed in such a heavy loading.

So please provide your comments and i am attaching my model for your reviews and comments.

RE: Instability at nodes

Instability at nodes

$
0
0

when I have done a project in staad message appear as instability in nodes due to weak spring....how to rectify it..

STAAD Foundation Pile Spring Issue

$
0
0

Hello, I am checking an existing tank foundation for a new tank. The tank is supported on piles with a pile cap. They are timber piles and we were given a specific k-value to use for the pile spring.

I am having some issues with STAAD Foundation Advanced with these springs. When I adjust the default values for the Kx, Ky, and Kz parameters and click away from the Pile Spring Definition screen, only some of the piles have kept the new values. I have tried saving the model after changing the K values but that doesn't seem to help.

Can someone please help with this issue? See screen shots for more explanation.

Before, with updated K values:

Pile Spring after:

HSS Design with Staad Pro

$
0
0

Hello,

I have problems with calculating some pipe supports.

The columns of the pipe supports are HSS and the cantilever beam that support the pipes are UPN.

Beam check: FAIL. The ration for the HSS is "Infinity", CRITICAL CONDITION: HSS T+SH+F+A.

Using instead 2xUPN 160 (back to back) the beam PASS and the ratio is 0.81.

What is the problem? STAAD.Pro can perform the check for HSS?

Thank you very much for your help.

Alex


Foundation Advanced - Linear Load

$
0
0

When modeling the lateral seismic loads on a mat, we calculate the resultant of an assumed triangular pressure under the base of a transformer and apply the load as a linear load in Foundation Advanced.  However, we noticed that the load was not applied to the plate elements unless the beginning and ending points coincided with the plate nodes.  Please review and advise.

RE: Single Angle Compression Design

Single Angle Compression Design

$
0
0

Long story short, I have a very simple model that consists of a single angle with a compressive force on it. The member is a 6x6x9/16. I am unable to derive the same unity as STAAD when using AISC 360-05 (360-10 gives same answer). I am getting 2.97 and STAAD is getting 2.43. Axial load is 71.7 kips.

I applied the ASD for the METHOD and TRACK 2 to see how STAAD was arriving at the 2.43 unity. The output showed that the only code check with a unity ratio was for "Check for Compression," which was expected, and that unity was 2.43. After digging into the output more, it became apparent the difference between my calcs and model was the KL/r ratio. Looking at E5(a) and E5(b) in AISC, I was (and still am) convinced that my situation falls under E5(a) since this is an "individual member." Given that the L/r ratio is greater than 80, I used equation E5-2 to get a KL/r of 202, or 200 due it being the max. However, STAAD's KL/r is listed as 181.19 in the compression check. I was finally able to find that STAAD was actually using equation E5-4, which is in E5(b).

My question is why did STAAD use section E5(b)? Is it a default? It seems like E5(a) would be the default if there was one. Am I missing something? Let me know what you guys think.

How can I apply Pdelta analysis for earthquake and wind load seperatley, also why is the small delta command used after performa pdelta text?

RE: ISM Problems importing into RAM from Revit

$
0
0
I just uploaded the Revit file, RAM SS model, and ISM model to that link you sent. The upper parapet problem work around you mention is viable, without much duplicate work on my end. The the floor problem is a much larger problem. I've also experienced problems getting beam cambers and stud counts to transfer back to Revit with the ISM method.

RE: 31.64m span intake tower footbridge

$
0
0
I don't see anything wrong with the file you sent. Since the braces are all fixed-ended, they are resisting some moments, in addition to axial forces. One consequence of making the sections larger double angles is that they will attract larger forces relative to the other members (larger moments in particular), and this could ultimately result in a higher interaction ratio.
For some tips on single angle design, note this saved search: communities.bentley.com/search

31.64m span intake tower footbridge

$
0
0

Please can the house help me confirm whether my analysis and design is okay. see attached file for the file. Thank you.[View:/cfs-file/__key/communityserver-discussions-components-files/5932/31.64m_5F00_Intake_5F00_Tower_5F00_Footbridge_5F00_ADOPTED.rar:940:0]


RE: External User Table Syntax Error

$
0
0

(Please visit the site to view this file)

RE: External User Table Syntax Error

$
0
0

I cannot upload the .upt file, I receive a message that says it cannot be uploaded. 

anything else I can upload?

RE: External User Table Syntax Error

$
0
0
Erika : Please zip the upt file first and then upload the zip file.

RE: External User Table Syntax Error

$
0
0

(Please visit the site to view this file)

RE: External User Table Syntax Error

Viewing all 23543 articles
Browse latest View live