STAAD Pro apprears to be checking my slenderness using r primed rather then just r I did some hand calcs to show it passing but staad is reading it as failure through trial and error I determined it was the r primed. I went and rotated my members to acurantely depict what was actually happening but they are still using r primed anyone have a fix for this?
↧