Quantcast
Channel: RAM | STAAD Forum - Recent Threads
Viewing all 23543 articles
Browse latest View live

AISI 1996 - STAAD Pro

$
0
0

Hi,

I am using staad pro first time for cold form steel design. I could not figure out how unity ratio is more than 1.5 for a particular member. see below scree shots and attached file.

Design strength Mz=16.5 KN-m ; Critical Load = 95.99 KN-m How Unity Ratio is >>1.5. Many Thanks in advance.

communities.bentley.com/.../STAAD-SPACE_2D00_1.docx


My staad file showing error as define input load command before .........Please help me to sort the above error and tell me what is the error and the reason behind it.

CIRCULAR SLOPE SLAB

$
0
0

I HAVE A G+3 CIRCULAR BUILDING OF 40 METER CLEAR SPAN DIAMETER. THE CIRCULAR SLAB OF THE THIRD FLOOR IS A SLOPED ONE, BUT NOW WHEN I AM TRYING TO ASSIGN THE LOAD BY GROUPING METHOD ITS NOT TAKING  THE ASSIGNED LOAD. IS THERE ANYONE WHO CAN GUIDE ME THROUGH IT??

THE SLOPE SLAB IS BENEATH THE DOME

-WITH REGARDS 

NISHIMON

Natural frequency calculation

$
0
0

I referred example 28 of American examples to calculate frequency. I gave cut off mode shape 100. In the output, I found that the frequency increases with each mode. I am confused which mode should be considered for obtaining natural frequency? I need to restrict the natural frequency to keep it away from RPM of the equipment.

Staad link ProStructures for rebar detailing

$
0
0

Hi All,

In Bentley solution Staad RCDC is very powerfull tool to design and 2D detailing concrete elements. Anyone have idea and experience on link Staad Pro or RCDC to ProStructures ( rebar )? Please add your opinion at this topic!

Thanks

Dynamic Analysis in MS Tower

$
0
0
Hi again,
 
I have a question about modelling dynamic response factor in MS Tower for guyed masts using the zgust parameter. 
 
I did a dynamic analysis and found the first mode was 0.97Hz.  As per AS1170 the dynamic response factor has to be calculated if the structure frequency < 1.
 
I calculated the dynamic response factor at each guy level (shown below).  What’s the simplest way to model the increased wind load at each guy level in MS Tower using zgust? 
 
If zgust is used in a load case, does it ignore the loading on the rest of the structure?  How do I combine these load cases into one combination?
 
/cfs-file/__key/communityserver-discussions-components-files/5932/6685.image003.png
 
 
Cheers,
Josh Kidd
 
From: Josh Kidd
Sent: Monday, 4 June 2018 11:39 AM
To:'RAMSTAAD@communities.bentley.com' <RAMSTAAD@communities.bentley.com>
Subject: RE: [RAM | STAAD Forum] Modelling parafil guys in microstran
 
Thanks for your help.
 
Cheers,
Josh  
 
From: Wentao Zhang <bounce-369039B8-30B0-4358-9D74-60598EB56469@communities.bentley.com>
Sent: Friday, 1 June 2018 11:55 AM
To:
RAMSTAAD@communities.bentley.com
Subject: RE: [RAM | STAAD Forum] Modelling parafil guys in microstran
 
/cfs-file/__key/communityserver-discussions-components-files/5932/7752.image004.png
/cfs-file/__key/communityserver-discussions-components-files/5932/2475.image005.jpg
 

Hi Josh,

As the question relates to material properties of Parafill Synthetic Cables, its best to check with the manufacturer.

I found this article :https://www.sciencedirect.com/science/article/pii/S0020768306003404 relating to research online and they suggest PR - Poissons Ratio - 0.5.

The unrestrained length Lo defaults to the length of the member(chord length) if nothing is inputted there. To induce tension, the value you enter for Lo would be less than your chord length (e.g if your chord length, distance between start and end node is 5 metres, your Lo of 4.9 metres is saying your cable has been pulled by 0.1 metres).

In the table on their website and your screenshots above they listExtension % at NBL(Net Breaking Load), and you also have theNBL itself

http://linearcomposites.net/?pageid=Parafil.xml

If we are going off the assumption that your cables are linear elastic (in tension) from No Load all the way up to NBL, you can work out the values the cable will be extended by with any given load.

Cheers,

WZ

View online

 

You received this notification because you subscribed to the forum.  To unsubscribe from only this thread,go here.

Flag this post as spam/abuse.

https://communities.bentley.com/notification/read?NotificationId=70a83273-4f92-4aec-ad6d-7780b4c3ea0d
 
This email and attachments: are confidential; may be protected by privilege and copyright; if received in error may not be used, copied, or kept; are not guaranteed to be virus-free; may not express the views of Kordia(R); do not designate an information system; and do not give rise to any liability for Kordia(R).

Testing batch mode column design vs RC interactive designer

$
0
0

In an effort to find a more efficient way in aggregating the output, I decided to give the RC interactive designer a try and compare it with the batch mode design results. Attached is a screenshot of the result from the batch mode vs the RC designer and you can tell that the results are different although both detected the same governing combination for designing the column. Where could the problem be? Which is the correct result knowing that I used aci-318 2005 in both modes and unified the parameters?

***WARNING: THE VALUE OF MOMENT AMPLIFICATION FACTORS KY OR KZ IS GREATER THAN 1.4

$
0
0

Dear Sir,

The members which are defined as truss also gives the warning of  MOMENT AMPLIFICATION FACTORS KY OR KZ IS GREATER THAN 1.4.

But the code specifies the check as per 9.3.2.2 for combined bending and axial compression case. As the bending moment in the truss member is 0, why does STAAD throw this warning.

How to address these warnings? The members still show as pass in the outpur. Is it ok to ignore these warnings?


Radius of gyration of a taper section

$
0
0

Dear All,

I am a tapered built-up section in Staad. I am wondering the way Staad calculates the radius of gyration of taper section. For a physical taper section, the radius of gyration should be considered as an average of the radius of gyration at the start and end of the section, wherein Staad is considering the radius of gyration at the less depth only. Please clarify.

max moments and deflection

$
0
0

Good day, I am new in staad, can someone help me with my question?

my question is how to get the maximum moments and deflection of each beams in staad? what load cases to be consider? I am planning to design beams manually and I am planning to get the maximum moments using staad. is it possible?

I will really appreciate any of your answers/suggestions. thank you very much!

zgust in MS Tower

$
0
0
Hi,
 
Can you please clarify how the load case below would load a tower in MS Tower?
 
   CASE 1303 Wind at  300.0 to X axis - pattern 3
         WL ANGLX 300.0  NOICE  ZGUST 17.78 ZGUST2 35.33 GFACT 0.66
 
 
 
Cheers,
Josh Kidd
 
From: Josh Kidd
Sent: Monday, 4 June 2018 11:39 AM
To:'RAMSTAAD@communities.bentley.com' <RAMSTAAD@communities.bentley.com>
Subject: RE: [RAM | STAAD Forum] Modelling parafil guys in microstran
 
Thanks for your help.
 
Cheers,
Josh  
 
From: Wentao Zhang <bounce-369039B8-30B0-4358-9D74-60598EB56469@communities.bentley.com>
Sent: Friday, 1 June 2018 11:55 AM
To:
RAMSTAAD@communities.bentley.com
Subject: RE: [RAM | STAAD Forum] Modelling parafil guys in microstran
 
 

Hi Josh,

As the question relates to material properties of Parafill Synthetic Cables, its best to check with the manufacturer.

I found this article :https://www.sciencedirect.com/science/article/pii/S0020768306003404 relating to research online and they suggest PR - Poissons Ratio - 0.5.

The unrestrained length Lo defaults to the length of the member(chord length) if nothing is inputted there. To induce tension, the value you enter for Lo would be less than your chord length (e.g if your chord length, distance between start and end node is 5 metres, your Lo of 4.9 metres is saying your cable has been pulled by 0.1 metres).

In the table on their website and your screenshots above they listExtension % at NBL(Net Breaking Load), and you also have theNBL itself

http://linearcomposites.net/?pageid=Parafil.xml

If we are going off the assumption that your cables are linear elastic (in tension) from No Load all the way up to NBL, you can work out the values the cable will be extended by with any given load.

Cheers,

WZ

View online

 

You received this notification because you subscribed to the forum.  To unsubscribe from only this thread,go here.

Flag this post as spam/abuse.

https://communities.bentley.com/notification/read?NotificationId=70a83273-4f92-4aec-ad6d-7780b4c3ea0d
 
This email and attachments: are confidential; may be protected by privilege and copyright; if received in error may not be used, copied, or kept; are not guaranteed to be virus-free; may not express the views of Kordia(R); do not designate an information system; and do not give rise to any liability for Kordia(R).

How to edit group description in RCDC

$
0
0

I once came across renaming a group of columns so that the group name will be reflected on the dxf plan wherever an instance of that group occurs. Unfortunately I don't know how I did it the first time, I know that I had access to edit the group name through the "Edit column description/prefix" option where the "Type" in the table showed GRP as for editing the group name, but now it only show COL for editing the prefix of each column in the group.

Any idea?

Error During Analytical Model Creation

$
0
0

When I try to "return to analytical modeling" from the physical modeller I get the following error: "Unrecognized Guid format." All I changed from the last time I updated the analytical model is some member releases. How can I resolve this error?

3D plate model

$
0
0

 Dear all,

i am trying to model 3D plate model with the application of compression springs both at base and side walls and have some doubts regarding that:

1) Initially i was trying to apply "load combination" command to add the respective loads but after going through staad literature i found that "repeat loads" were to be used in this case.

Upon the application of repeat loads i noticed close to 50% decrease in the bending moment . Isn't this decrease too large or am i making some mistake?

2) In order to reduce bending moments, i applied joints using the release option in plate specifications for the whole structure. But to my dismay, i see no perceptible decrease in the maximum bending moment (rather an increase in bending moments?? why is this happening?

3) Also regarding application of release, i am confused about direction in which they are to be applied. Figures below show 2 directions in which releases can be applied, which one of them is correct? 

  OR    

4) Also, i would need some advice on the support conditions to be employed. Should i use fix boundary conditions at corners of base (with intermediate nodes being attached to spring) or should i go for Pinned/fixed boundary condition on top of side wall as shown below

SAF

$
0
0

Hi,

I have the following questions on Staad Advanced Foundation:

1.For bearing capacity checks does the software use the Linear Soil pressure method or the Reduced Effective Area method.

2.Is there an option to select granular or cohesive soil as the checks differs.

3.Does the software allow to set the percentage of base compression.

4.Is there allowable bearing capacity input for multiple load cases i.e. operating combinations, seismic combinations...

Thank you


SFA rigid foundations and supported nodes from STAAD.Pro

$
0
0

I have a question regarding pile supported mat foundations.  In the Help file there is a this tip:

Tip: For rigid foundations (i.e., isolated, combined, pilecap, etc.) the supported nodes in the STAAD.Pro model should be oriented to the top of the footing. However, for mat foundations, the supported nodes in the STAAD.Pro model should be modeled at the bottom of the footing.

When modeling from STAA.Pro import Y elevation is at 0, when creating my pile supported mat for a 4'-0" thick mat my Y elevation should be -4'-0".  Am I assuming correctly that for my piles, especially fixed head piles, that the embedment depth of 6" or 12" that their Y elevation would be -3'-6" or -3'-0" respectively to get correct pile reactions and moment in the pile head?

Thanks,

Russ

Nonlinear Oddity

$
0
0

I modeled two identical beams with the same distributed load. Each beam has a short vertical member connected at each end. The only difference is one beam is a single element. The other one is divided into 10 segments. For static linear analysis, I get the same results for each beam as would be expected. However, when I run a nonlinear analysis, the beam with only one segment gets wildly incorrect values. Here's a screen shot of the Mz bending moments. They should be the same but notice how different they are.

I reported this as a bug but the service ticket was closed. I understand that breaking an element up into more parts can give better nonlinear results but I wouldn't have expected this large of a difference. Also, the loads are such that the beams stay in the linear range. You can look at the deflection of the center node of the subdivided beam and see that it behaves linearly.

I've attached the .std file communities.bentley.com/.../Nonlinear-Test.std so others can try this.  Any thoughts on what is happening here?

STAAD Foundation Advanced Envelope Generation Error

$
0
0

I am using SFA Connect Edition version 8.4.0.21 and am getting the an error when I am trying to generate the moment envelope for a mat foundation.  The error states that no load case associated to the current job is defined as Ultimate Loading.  I have load combinations that are set as Ultimate so I don't understand why I am getting this error.  See the attached picture.  I have also attached my SFA file.communities.bentley.com/.../NorthEgressStair_5F00_90_5F00_foundation.sfa

Staad 3D plate model

$
0
0

 Dear all,

i am trying to model 3D plate model with the application of compression springs both at base and side walls and have some doubts regarding that:

1) Initially i was trying to apply "load combination" command to add the respective loads but after going through staad literature i found that "repeat loads" were to be used in this case.

Upon the application of repeat loads i noticed close to 50% decrease in the bending moment . Isn't this decrease too large or am i making some mistake?

2) In order to reduce bending moments, i applied joints using the release option in plate specifications for the whole structure. But to my dismay, i see no perceptible decrease in the maximum bending moment (rather an increase in bending moments?? why is this happening?

3) Also regarding application of release, i am confused about direction in which they are to be applied. Figures below show 2 directions in which releases can be applied, which one of them is correct? 

  OR    

4) Also, i would need some advice on the support conditions to be employed. Should i use fix boundary conditions at corners of base (with intermediate nodes being attached to spring) or should i go for Pinned/fixed boundary condition on top of side wall as shown below

Solución para Bases de Columnas:

$
0
0

Solución para Bases de Columnas:

Mi pregunta es como modelar una Articulación mediante bulón y charnela,,, y si con ram connection existe el modo de diseñar este tipo de solución para bases articuladas,,, saludos y gracias de antemano por la ayuda