Quantcast
Channel: RAM | STAAD Forum - Recent Threads
Viewing all 23543 articles
Browse latest View live

RE: Groups

$
0
0
I am not sure whether I fully understood the question but it seems like you have assigned same beams or elements to multiple groups and would like to get a list of all the groups to which the particular beam/element has been assigned to. If that is your question, the answer is there is no direct way to do that. However there are couple of things you can try out. You can go to the editor ( Edit > Edit Input Command File ) . Go to the section of the command file where you have the group definitions and the use the find/search tool from within the editor to search for the beam/plate number. The search would find the beam number. Press F3 to find subsequent occurrences of the same search term. That way you would be able to find all the group names in which that beam/element appear. An alternative graphical way would be to go to Select > By Group Name, select the groups and visually check what are the groups for which the particular beam/element gets highlighted.

If this does not answer your question, please explain in a little more detail as to what you are trying to do with the groups and I will try to answer.

Groups

$
0
0

Hello,

I have a model whith some beams/shell/geometry/floor groups defined

Can I list for beam or element all the groups that belongs ?

Thanks in advanced

RE: How to do in STAAD.Pro

$
0
0
I do not have any question paper as such but the best thing you can do is to refer to structural engineering textbooks. I am sure in the appropriate sections of these books, you will find examples of bending moment/shear force diagrams for beams/frames. You can model these in STAAD.Pro using simple models with appropriate supports and releases, as we already discussed about in this forum post.

RE: Tee Section Cut Of W Shape

$
0
0
Error found while designing member 29.
Error : No records are available in section database.
kindly hel me

RE: Response Spectrum Analysis on Large Model (STAAD)

$
0
0

You can use the MODE SELECT xxx  … command which would restrict the response to the set of modes limited by the command.  

Please refer to the section 5.30.2 of the technical reference manual titled Mode Selection for more details on this command.

Also if you have the license for the advanced analysis engine, you can use the Ritz Vector Method of eigensolution as opposed to the default Subspace Iteration. This method is able to account for the dynamic loading and is able to extract the relevant modes that can have significant effect on the dynamic response.  More details on that can be found at Technical Reference Manual section 1.18.3.1.2 titled Load-Dependent Ritz Vectors. The software can be instructed to use the Ritz Vector method of eigensolution by choosing the menu option Commands > Miscellaneous > Set Eigen Method > Load Dependent Ritz Vectors.

Response Spectrum Analysis on Large Model (STAAD)

$
0
0

I'm running a response spectrum analysis on a fairly large model (11,000 nodes) in STAAD (SELECT Series 6 v20.07.11.50) and combining the modal results using the CQC method. Due to the size of the model there are numerous modes, most of which are not significant. Is there a way to set a modal response significance factor so that when the modal responses are combing using the CQC method only significant modes will be combined and the rest ignored? Thanks

RE: Tee Section Cut Of W Shape

$
0
0
Which design code are you using ? Using the batch mode of design should help. If not, can you please upload the model ?

RE: wind loads on walls with varying heights in ram

$
0
0
I searched in the help file along with in the forums but I can't seem to find how you would do this. If Ram cannot do the wind loads properly, I would like to be able to manually add horizontal distributed loads to the framing but there doesn't seem to be a way to do this. You can make nodal loads but they seem to be applied with story height. Because it is locked to story height, you have no way to adjust for sloped walls (single pitched roof).

wind loads on walls with varying heights in ram

$
0
0

I'm modeling a structure in Ram that has a single pitched roof.  This roof also has a parapet on top that is 2.5 feet high.  Because of the pitched roof and the size of the structure (130'x160') there is quite a difference in roof heights from the low point to the high point.  I added the parapet as a wall on top of the roof.  I don't know if the program then uses that extra wall height or does it just use the story height when applying the wind loading.

How do you apply wind loading to a wall that is not a constant height?  There doesn't seem to be an option for that.  You can do story height or an offset from a story height.  Do you just pick the tallest part of your structure and the program is smart enough to apply apply a force to the walls below that point?

Thank you. 

RE: I am receiving errors. "...floor diaphragm is present in the model. Wind Load definition should be defined after Floor Diaphragm definition..."

$
0
0

I am still having the following warnings... Please help...


WARNING - Load and release specified together for member 86 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 95 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 98 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 99 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 100 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 101 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 102 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 104 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 176 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 178 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 86 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 95 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 98 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 99 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 100 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 101 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 102 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 104 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 176 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 178 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6

RE: I am receiving errors. "...floor diaphragm is present in the model. Wind Load definition should be defined after Floor Diaphragm definition..."

$
0
0

(Please visit the site to view this file)

RE: PROBABLE CAUSE NEGATIVE DIAGONAL =>LDLT MTX K-MATRIX DIAG...

$
0
0
Thanks for uploading the model. The error that you reported is typically associated with an ill conditioned stiffness matrix. What is the version of STAAD.Pro you are using ? If it is not the latest 20.07.11.50, I would suggest you do that. I have been able to successfully analyze the model using both basic and advanced solvers in that version. If you have license for advanced analysis engine, then you should still be able to analyze this model using older versions of the software. However I would recommend upgrading the software to the latest version.

PROBABLE CAUSE NEGATIVE DIAGONAL =>LDLT MTX K-MATRIX DIAG...

$
0
0

Dear all,

I have modelled a 3D canopy structure with solid elements which will be acting as the fabric. I am having issues running the model as it is coming up with issues as shown in the subject.

The solid is a hyperbolic shape as shown in purple. The rest are CHS sections.

Any help would be appreciated.

Thanks

RE: I am receiving errors. "...floor diaphragm is present in the model. Wind Load definition should be defined after Floor Diaphragm definition..."

$
0
0

You defined FX FY and FZ releases for certain members. That means these members cannot transfer any axial force or shear force to the supporting members which is not realistic.  So the following releases were commented out.

*MEMBER RELEASE

*86 95 98 TO 102 104 176 178 START FX FY FZ

*86 95 98 TO 102 104 176 178 END FX FY FZ

A LOAD LIST command as shown next was added before the CONCRETE DESIGN to ensure that design is carried out for load combinations only.

LOAD LIST 7 TO 9

START CONCRETE DESIGN

CODE ACI

The following commands were added after each UBC load case

PERFORM ANALYSIS

CHANGE

There were a number of redundant analysis commands which were commented out.

You used both PERFORM ANALYSIS and PDELTA in the model. Normally if you are using the ACI code you should be using PDELTA. A PDELTA 15 ANALYSIS was added so that an iterative pdelta analysis is carried out.

For PDELTA ANALYSIS all the LOAD COMBINATIONs  have to be replaced by REPEAT LOADs. So LOAD COMBINATION 7 8 9 were replaced by REPEAT LOADs. To understand the difference between REPEAT LOADs and LOAD COMBINATIONs you may refer to the following tech note

For wind load to generate successfully, it has to act on closed panels. For wind acting in Z direction, there are no closed panels at Z =2.5m and between X=14.17m to X=16.27m. So you will either need to define some members or you need to restrict the wind load generation to the face at Z=0. For now, I have done the later by using a ZRANGE command

A modified file is attached for your reference.

(Please visit the site to view this file)

I am receiving errors. "...floor diaphragm is present in the model. Wind Load definition should be defined after Floor Diaphragm definition..."

$
0
0

I am having so many error and warnings everytime I run analysis.. PLEASE HELP ME...

68. DEFINE WIND LOAD

*** NOTE: If any floor diaphragm is present in the model Wind Load definition
should be defined after Floor Diaphragm definition. Otherwise wind
load generation may be unsuccessful during analysis.

69. TYPE 1 WIND 1
70. <! STAAD PRO GENERATED DATA DO NOT MODIFY !!!
71. ASCE-7-2010:PARAMS 200.000 KMPH 0 3 1 0 0.000 FT 0.000 FT 0.000 FT 1 -
72. 1 6.200 M 16.270 M 7.000 M 2.000 0.010 0 -
73. 0 0 0 0 1.086 1.000 1.000 0.850 0 -
74. 0 0 0 0.893 0.800 -0.550
75. !> END GENERATED DATA BLOCK
76. INT 2.14606 2.14606 2.15164 2.1571 2.16244 2.16767 2.1728 2.17783 2.18275 -
77. 2.18759 2.19234 2.197 2.20158 2.20608 2.21051 2.20931 HEIG 0 4.572 4.69723 -
78. 4.82246 4.94769 5.07292 5.19815 5.32338 5.44862 5.57385 5.69908 -
79. 5.82431 5.94954 6.07477 6.2 6.2
80. LOAD 1 LOADTYPE SEISMIC TITLE UBCLOAD@X
81. UBC LOAD X 1
82. SELFWEIGHT X 1 LIST 20 TO 22 24 25 27 TO 32 34 35 39 TO 43 45 TO 51 53 55 -
83. 58 TO 79 86 87 93 TO 104 156 158 TO 161 163 TO 170 172 174 TO 179 -
84. 195 TO 198
85. SELFWEIGHT Y 1 LIST 20 TO 22 24 25 27 TO 32 34 35 39 TO 43 45 TO 51 53 55 -
86. 58 TO 79 86 87 93 TO 104 156 158 TO 161 163 TO 170 172 174 TO 179 -

100. FLOOR LOAD
101. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 0 4.19 ZRANGE 0 1.2 GY
**NOTE** about Floor/OneWay Loads/Weights.
Please note that depending on the shape of the floor you may
have to break up the FLOOR/ONEWAY LOAD into multiple commands.
For details please refer to Technical Reference Manual
Section 5.32.4.2 Note d and/or "5.32.4.3 Note f.

102. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 4.19 8.19 ZRANGE 0 1.2 GY
103. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 8.19 12.19 ZRANGE 0 1.2 GY
104. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 12.19 14.17 ZRANGE 0 1.2 GY
105. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 0 4.19 ZRANGE 1.2 2.5 GY
106. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 4.19 8.19 ZRANGE 1.2 2.5 GY
107. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 8.19 12.19 ZRANGE 1.2 2.5 GY
108. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 12.19 14.17 ZRANGE 1.2 2.5 GY
109. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 14.17 14.92 ZRANGE 1.2 2.5 GY
110. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 12.19 14.17 ZRANGE 2.5 7 GY
111. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 14.17 14.92 ZRANGE 2.5 7 GY
112. MEMBER LOAD
113. 87 UNI GY -3.84
114. FLOOR LOAD
115. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 14.92 16.27 ZRANGE 2.5 7 GY
116. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 0 4.19 ZRANGE 2.5 7 GY
117. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 4.19 8.19 ZRANGE 2.5 7 GY
118. YRANGE 3.5 3.5 FLOAD -2.33 XRANGE 8.19 12.19 ZRANGE 2.5 7 GY
119. LOAD 6 LOADTYPE LIVE TITLE LIVELOAD
120. FLOOR LOAD
121. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 0 4.19 ZRANGE 0 1.2 GY
122. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 4.19 8.19 ZRANGE 0 1.2 GY
123. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 8.19 12.19 ZRANGE 0 1.2 GY
124. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 12.19 14.17 ZRANGE 0 1.2 GY
STAAD SPACE -- PAGE NO. 4

125. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 0 4.19 ZRANGE 1.2 2.5 GY
126. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 4.19 8.19 ZRANGE 1.2 2.5 GY
127. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 8.19 12.19 ZRANGE 1.2 2.5 GY
128. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 12.19 14.17 ZRANGE 1.2 2.5 GY
129. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 14.17 14.92 ZRANGE 1.2 2.5 GY
130. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 12.19 14.17 ZRANGE 2.5 7 GY
131. MEMBER LOAD
132. 87 UNI GY -4.608
133. FLOOR LOAD
134. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 14.17 14.92 ZRANGE 2.5 7 GY
135. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 14.92 16.27 ZRANGE 2.5 7 GY
136. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 0 4.19 ZRANGE 2.5 7 GY
137. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 4.19 8.19 ZRANGE 2.5 7 GY
138. YRANGE 3.5 3.5 FLOAD -1.92 XRANGE 8.19 12.19 ZRANGE 2.5 7 GY
139. LOAD 3 LOADTYPE WIND TITLE WINDLOAD@X
140. WIND LOAD X 1 TYPE 1
141. LOAD 4 LOADTYPE WIND TITLE WINDLOAD@Z
142. WIND LOAD Z 1 TYPE 1
**WARNING-fx fy fz wind forces: 0.0000E+00 0.0000E+00 3.9434E+00
at coordinates: 1.4170E+01 0.0000E+00 2.5000E+00 ignored.
143. LOAD COMB 7 1.4DL


**NOTE- IF A COMBINATION INCLUDES A DYNAMIC CASE OR IS AN SRSS OR ABS COMBINATION
THEN RESULTS CANNOT BE COMPUTED PROPERLY.
GLOBAL CORNER FORCES
JOINT FX FY FZ MX MY MZ

ELE.NO. 180 FOR LOAD CASE 1
15 -4.2564E+00 -3.1848E+00 -2.1056E+00 1.7381E+00 1.3986E+00 -7.9437E+00
17 -1.4472E+00 4.4383E+00 -1.2000E+00 -2.0852E+00 -6.9257E-01 -8.3271E+00
45 4.2666E+00 2.2803E+00 2.8335E+00 3.7921E-01 3.4598E-01 -5.1612E+00
44 1.4370E+00 -3.5338E+00 4.7214E-01 -1.5363E+00 -1.0520E+00 -6.7188E+00
ELE.NO. 180 FOR LOAD CASE 2
15 -3.1255E+00 -5.6294E+00 -6.3103E-01 7.4865E+00 -3.5527E+00 -4.0265E+00
17 -3.0179E-01 -5.5946E+00 3.5525E+00 7.4145E+00 8.6497E-01 4.4825E+00
45 -6.3550E-01 5.4250E+00 -2.5710E+00 -7.7927E-01 1.6999E+00 -3.7775E+00
44 4.0628E+00 5.7991E+00 -3.5053E-01 -6.5290E-01 9.8775E-01 4.0325E+00
ELE.NO. 180 FOR LOAD CASE 5
15 -3.1856E-01 1.2541E+01 -3.9736E-01 -5.7338E+00 2.3187E-01 1.2565E+01
17 -1.1103E-02 4.2564E+00 -3.4660E-01 -3.8305E+00 -2.1803E-01 3.1383E-01
45 2.0933E-01 -1.3822E+01 4.4102E-01 -8.4070E+00 2.4802E-01 2.0204E+01
44 1.2034E-01 -2.9756E+00 3.0295E-01 -2.1855E+00 -2.6186E-01 6.9963E+00
ELE.NO. 180 FOR LOAD CASE 6
15 -7.2695E-03 2.4235E+00 -8.3185E-02 -1.1977E+00 1.0136E-01 2.2848E+00
17 -1.7531E-02 1.1846E+00 -1.3933E-01 -9.4107E-01 -8.5458E-02 -3.2973E-01
45 5.2739E-02 -2.6850E+00 1.4643E-01 -1.6098E+00 4.6987E-02 3.6015E+00
44 -2.7939E-02 -9.2306E-01 7.6082E-02 -5.8106E-01 -6.2889E-02 7.3022E-01
ELE.NO. 180 FOR LOAD CASE 3
15 5.1259E-02 3.7004E-01 -1.4643E+00 -2.1669E-01 1.6392E+00 -5.9872E-01
17 -4.5918E+00 1.6118E+00 -9.2568E-01 -8.5887E-01 -1.3001E+00 -1.9570E+00
45 2.1355E-01 -5.6937E-01 2.2261E+00 -5.1899E-01 9.0543E-01 -7.7534E-02
44 4.3270E+00 -1.4125E+00 1.6389E-01 -7.8368E-01 -1.2445E+00 -1.7346E+00
ELE.NO. 180 FOR LOAD CASE 4
15 -9.8397E-01 -1.9621E+00 1.1614E+00 2.6396E+00 -7.5325E-01 -1.3833E+00
17 -6.7409E+00 -2.0121E+00 6.2262E+00 2.6606E+00 1.6446E+00 1.6278E+00
45 4.8780E+00 1.9212E+00 -4.0138E+00 -2.8887E-01 -4.0332E+00 -1.3140E+00
44 2.8469E+00 2.0530E+00 -3.3737E+00 -2.4230E-01 3.1418E+00 1.4502E+00
ELE.NO. 180 FOR LOAD CASE 7
15 -4.4598E-01 1.7557E+01 -5.5630E-01 -8.0273E+00 3.2461E-01 1.7591E+01
17 -1.5546E-02 5.9589E+00 -4.8524E-01 -5.3627E+00 -3.0524E-01 4.3936E-01
45 2.9306E-01 -1.9350E+01 6.1742E-01 -1.1770E+01 3.4722E-01 2.8286E+01
44 1.6847E-01 -4.1659E+00 4.2412E-01 -3.0598E+00 -3.6659E-01 9.7948E+00
ELE.NO. 180 FOR LOAD CASE 8
15 -4.5834E-01 2.1677E+01 -6.9768E-01 -1.0064E+01 4.9691E-01 2.1475E+01
17 -4.5348E-02 7.9727E+00 -7.2207E-01 -6.9625E+00 -4.5050E-01 -1.2119E-01
45 3.8271E-01 -2.3915E+01 8.6633E-01 -1.4506E+01 4.2708E-01 3.4408E+01
44 1.2098E-01 -5.7351E+00 5.5343E-01 -4.0476E+00 -4.7349E-01 1.1036E+01
ELE.NO. 180 FOR LOAD CASE 9
15 -3.2583E-01 1.4964E+01 -4.8053E-01 -6.9316E+00 3.3322E-01 1.4850E+01
17 -2.8635E-02 5.4410E+00 -4.8592E-01 -4.7716E+00 -3.0348E-01 -1.5907E-02
45 2.6207E-01 -1.6507E+01 5.8744E-01 -1.0017E+01 2.9500E-01 2.3805E+01
44 9.2398E-02 -3.8987E+00 3.7901E-01 -2.7666E+00 -3.2474E-01 7.7265E+00

ELE.NO. 181 FOR LOAD CASE 1
17 -3.9995E-01 -3.3346E+00 -2.7273E-02 1.9051E+00 7.5496E-01 -5.5625E+00
19 -1.1483E+00 9.6106E-01 -1.2734E-01 -4.8533E-01 -1.3298E-01 -4.0237E+00
46 2.0205E+00 2.7882E+00 5.9183E-01 1.1733E+00 -8.2633E-01 -3.6700E+00
45 -4.7227E-01 -4.1465E-01 -4.3721E-01 2.5520E-01 2.0435E-01 -1.7409E+00
STAAD SPACE -- PAGE NO. 22



ELEMENT FORCES FORCE,LENGTH UNITS= KN METE
--------------
GLOBAL CORNER FORCES
JOINT FX FY FZ MX MY MZ
ELE.NO. 181 FOR LOAD CASE 2
17 -1.5921E+00 -6.0116E+00 -1.0187E+00 7.4891E+00 -1.4064E+00 -4.4392E+00
19 -2.4916E+00 -5.9963E+00 1.4680E+00 7.5188E+00 -6.0842E-01 4.4018E+00
46 2.2349E-01 6.0187E+00 -2.4284E-01 -3.0789E-01 1.5605E+00 -4.0251E+00
45 3.8603E+00 5.9893E+00 -2.0645E-01 -2.9051E-01 4.5432E-01 3.9732E+00
ELE.NO. 181 FOR LOAD CASE 5
17 1.3419E-01 3.9359E+00 -6.0106E-02 -5.9839E-01 9.8604E-02 8.0977E+00
19 1.1831E-01 -6.2047E+00 -2.1846E-01 1.6940E+00 -8.7855E-02 9.6141E+00
46 -1.1935E-01 -6.7493E+00 1.4270E-01 -3.5922E+00 8.7311E-02 1.6163E+01
45 -1.3315E-01 9.0181E+00 1.3586E-01 5.2191E+00 -9.8059E-02 1.7941E+01
ELE.NO. 181 FOR LOAD CASE 6
17 1.4700E-02 4.1565E-01 -2.4383E-02 2.0695E-02 3.9656E-02 1.2572E+00
19 2.0617E-02 -1.3869E+00 -7.1680E-02 4.3362E-01 -3.2053E-02 1.9092E+00
46 2.8941E-03 -9.0975E-01 6.1085E-02 -4.2162E-01 1.9683E-02 2.6359E+00
45 -3.8211E-02 1.8810E+00 3.4978E-02 1.1328E+00 -2.7286E-02 3.3845E+00
ELE.NO. 181 FOR LOAD CASE 3
17 1.3827E+00 -6.4359E-01 -8.6674E-02 3.9909E-01 6.9976E-01 -8.1837E-01
19 -3.0975E+00 -1.8482E-01 -2.8091E-02 7.9088E-02 -5.3938E-01 -2.6873E-01
46 -7.9240E-01 4.9278E-01 5.4253E-01 2.3520E-01 1.5474E-01 -4.0194E-01
45 2.5072E+00 3.3564E-01 -4.2777E-01 2.8072E-01 -3.1511E-01 2.5722E-01
ELE.NO. 181 FOR LOAD CASE 4
17 4.3328E+00 -2.1471E+00 6.4001E+00 2.6679E+00 -2.1507E+00 -1.5689E+00
19 -5.0368E+00 -2.1087E+00 5.9700E+00 2.6374E+00 2.4036E+00 1.5623E+00
46 6.8073E-01 2.1149E+00 -5.7588E+00 -1.0207E-01 -5.2249E+00 -1.4270E+00
45 2.3208E-02 2.1409E+00 -6.6113E+00 -9.6304E-02 4.9719E+00 1.4089E+00
ELE.NO. 181 FOR LOAD CASE 7
17 1.8787E-01 5.5103E+00 -8.4129E-02 -8.3775E-01 1.3803E-01 1.1337E+01
19 1.6564E-01 -8.6866E+00 -3.0582E-01 2.3716E+00 -1.2298E-01 1.3460E+01
46 -1.6709E-01 -9.4490E+00 1.9976E-01 -5.0290E+00 1.2222E-01 2.2628E+01
45 -1.8642E-01 1.2625E+01 1.9018E-01 7.3068E+00 -1.3727E-01 2.5118E+01
ELE.NO. 181 FOR LOAD CASE 8
17 2.1286E-01 6.2169E+00 -1.2558E-01 -8.0257E-01 2.0545E-01 1.3474E+01
19 2.0069E-01 -1.1044E+01 -4.2768E-01 3.1088E+00 -1.7748E-01 1.6705E+01
46 -1.6218E-01 -1.0996E+01 3.0361E-01 -5.7458E+00 1.5569E-01 2.7109E+01
45 -2.5138E-01 1.5823E+01 2.4964E-01 9.2326E+00 -1.8366E-01 3.0871E+01
ELE.NO. 181 FOR LOAD CASE 9
17 1.4890E-01 4.3516E+00 -8.4480E-02 -5.7770E-01 1.3826E-01 9.3548E+00
19 1.3893E-01 -7.5916E+00 -2.9013E-01 2.1276E+00 -1.1990E-01 1.1523E+01
46 -1.1646E-01 -7.6590E+00 2.0378E-01 -4.0138E+00 1.0699E-01 1.8799E+01
45 -1.7137E-01 1.0899E+01 1.7083E-01 6.3520E+00 -1.2534E-01 2.1326E+01

ELE.NO. 182 FOR LOAD CASE 1
19 -2.1750E-01 -3.5737E+00 9.6425E-02 1.9162E+00 8.7718E-01 -6.0778E+00
21 -3.7351E+00 1.2774E+00 6.6329E-01 -5.8784E-01 -2.8556E-01 -4.2744E+00
47 2.7628E+00 3.1140E+00 5.2250E-01 1.3965E+00 -1.1892E+00 -4.3881E+00
46 1.1898E+00 -8.1770E-01 -1.2822E+00 3.0716E-02 5.9757E-01 -2.8251E+00
ELE.NO. 182 FOR LOAD CASE 2
19 7.5759E-01 -6.7422E+00 8.5149E-02 8.1128E+00 -4.8348E-01 -5.0598E+00
21 -2.5880E+00 -6.6551E+00 8.3962E-01 8.3245E+00 -8.8420E-01 4.7165E+00
47 6.7950E-01 6.9161E+00 -2.9050E-01 -1.3993E-01 2.4867E-01 -4.8791E+00
46 1.1509E+00 6.4813E+00 -6.3427E-01 -2.2048E-01 1.1190E+00 4.1786E+00

*WARNING- APPLIED SELFWEIGHT IS LESS THAN TOTAL WEIGHT OF ALL
STRUCTURAL ELEMENTS IN LOAD CASE 1 ALONG X.
THIS COULD BE DUE TO SELFWEIGHT APPLIED TO SPECIFIC
LIST OF MEMBERS/PLATES/SOLIDS/SURFACES.
TOTAL UNFACTORED WEIGHT OF THE STRUCTURE = 667.234 KN
TOTAL UNFACTORED WEIGHT OF THE STRUCTURE APPLIED = 404.510 KN

WARNING - Load and release specified together for member 86 dir. 1
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 86 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 95 dir. 1
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 95 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 98 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 98 dir. 3
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 99 dir. 1
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 99 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 100 dir. 1
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 100 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 101 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 101 dir. 1
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 102 dir. 1
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 102 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 104 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 104 dir. 3
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 176 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 176 dir. 3
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 178 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 1
WARNING - Load and release specified together for member 178 dir. 3
Check member load paths. This LOAD (or more) IGNORED in case no. 1
STAAD SPACE -- PAGE NO. 6


*WARNING- APPLIED SELFWEIGHT IS LESS THAN TOTAL WEIGHT OF ALL
STRUCTURAL ELEMENTS IN LOAD CASE 2 ALONG Z.
THIS COULD BE DUE TO SELFWEIGHT APPLIED TO SPECIFIC
LIST OF MEMBERS/PLATES/SOLIDS/SURFACES.
TOTAL UNFACTORED WEIGHT OF THE STRUCTURE = 667.234 KN
TOTAL UNFACTORED WEIGHT OF THE STRUCTURE APPLIED = 404.510 KN

WARNING - Load and release specified together for member 86 dir. 3
Check member load paths. This LOAD (or more) IGNORED in case no. 2
WARNING - Load and release specified together for member 95 dir. 3
Check member load paths. This LOAD (or more) IGNORED in case no. 2
WARNING - Load and release specified together for member 98 dir. 1
Check member load paths. This LOAD (or more) IGNORED in case no. 2
WARNING - Load and release specified together for member 99 dir. 3
Check member load paths. This LOAD (or more) IGNORED in case no. 2
WARNING - Load and release specified together for member 100 dir. 3
Check member load paths. This LOAD (or more) IGNORED in case no. 2
WARNING - Load and release specified together for member 101 dir. 3
Check member load paths. This LOAD (or more) IGNORED in case no. 2
WARNING - Load and release specified together for member 102 dir. 3
Check member load paths. This LOAD (or more) IGNORED in case no. 2
WARNING - Load and release specified together for member 104 dir. 1
Check member load paths. This LOAD (or more) IGNORED in case no. 2
WARNING - Load and release specified together for member 176 dir. 1
Check member load paths. This LOAD (or more) IGNORED in case no. 2
WARNING - Load and release specified together for member 178 dir. 1
Check member load paths. This LOAD (or more) IGNORED in case no. 2

*WARNING- APPLIED SELFWEIGHT IS LESS THAN TOTAL WEIGHT OF ALL
STRUCTURAL ELEMENTS IN LOAD CASE 5 ALONG Y.
THIS COULD BE DUE TO SELFWEIGHT APPLIED TO SPECIFIC
LIST OF MEMBERS/PLATES/SOLIDS/SURFACES.
TOTAL UNFACTORED WEIGHT OF THE STRUCTURE = 667.234 KN
TOTAL UNFACTORED WEIGHT OF THE STRUCTURE APPLIED = 404.510 KN

WARNING - Load and release specified together for member 86 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 95 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 98 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 99 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 100 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 101 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 102 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 104 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 176 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
WARNING - Load and release specified together for member 178 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 5
STAAD SPACE -- PAGE NO. 7

WARNING - Load and release specified together for member 86 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 95 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 98 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 99 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 100 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 101 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 102 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 104 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 176 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6
WARNING - Load and release specified together for member 178 dir. 2
Check member load paths. This LOAD (or more) IGNORED in case no. 6

**WARNING: IF THIS UBC/IBC ANALYSIS HAS TENSION/COMPRESSION
OR REPEAT LOAD OR RE-ANALYSIS OR SELECT OPTIMIZE, THEN EACH

UBC/IBC CASE SHOULD BE FOLLOWED BY PERFORM ANALYSIS & CHANGE.


RE: How to model a corrugated steel plate

$
0
0
Thank you Sye for your reply but it wasn't what I expected. As you know the corrugated plate has a preferential direction to distribute loads: the direction parallel to the "wave" of the corrugated plate. The transverse direction usually it considered to do not transfer any load. In that way I would like to model this particular behavior increasing the stiffness along the major inertia of the corrugated plate (the direction parallel to the "wave" of the corrugated plate). If I change the thickness or I change the Young modulus (as you suggested to me) I will change the both inertia (major and minor) but it's what I don't want to do. Moreover in that way I would like to consider the bracing effect due to the corrugated plate. What I'm talking about is a modelling of a steel prefabricated cabin usually applied on offshore and onshore design. I hope to explained better my needs. Awaiting for your answer.

Thank you and regards

Riccardo

How to model a corrugated steel plate

$
0
0

I have to model a corrugated steel plate. I would like to use plate or surface elements. How can I do it?

It is possible to change the stiffness parameters of the plate or surfaces elements?

Thank you.

Riccardo

RE: Tee Section Cut Of W Shape

$
0
0
I dont know which value is suitable for DMAX DMIN CB etc parameters for my steel structure design using code BS5950 1/2000.. and also tell me which parameters i should select for steel structures

Tee Section Cut Of W Shape

$
0
0

STAAD.Pro 2007.09.31 shows the following error during analysis:

 10973. 645 TABLE T W200X21
 
   *** STAAD.Pro ERROR MESSAGE ***
   T SHAPE FOR W200X21      IS NOT AVAILABLE
 
   **ERROR- IN READING MEMBER PROPERTIES. CHECK DATA FORMAT CAREFULLY.

The section is from Canadian Tables.
There is a TR 4449 which relates to the similar issue with Steel Designer, however the suggestion made by Binith may explain the cause of the above mentioned error in batch mode:

Solution  
Description  TR Number: 4449
Workaround: Issue has been logged in DevTrack - ID: 4449. As a work around solution users are suggested to use the batch mode for design of these tee sections.
 
Attributes  Service Management, Public, Released
Problem  
Description  Certain Tee Sections Not Checked in Steel Designer
In the attached model, some of the WT sections (tee shapes cut from wide flanges) are giving this message:

Member M533
Error found while designing member 533.
Error : No records are available in section database.
This is referring to physical member # 533
Interestingly, this is not happening for all WT sections only the WT6x26.5 and WT7x26.5 shapes.

Binith has suggested the following:
The problem seems to be with the reading of the section properties while performing the design.
The member 2564 in the model is defined as a Tee cut from a T W12X53 section. However, when
looking up the database for section properties, the program is looking for a “W12x52” section. I
think it might be some kind of rounding error whereby, when defining the Tee we take d/2 ( 53 / 2
= 26.5) but when getting it back to look up the db, we might be loosing the decimal part and using
26x2 = 52. Could you please log this in Devtrack. 

TR Number: 4449
Product: STAAD.Pro V8i
Version: 20.07.09.11
Area: General, Problem ID#: 81909, TROUBLEREPORT
Attributes  Service Management, Public, Released

STEEL STRUCTURE DESIGNIN

$
0
0

I dont know which value is suitable for DMAX DMIN CB etc parameters for my steel structure design using code BS5950 1/2000.. and also tell me which parameters i should select for steel structures..