RE: Using STAAD to design single angle members

No, it is actually a moment frame from an outside contractor. 

View Article


RE: RAM Connection CE - No connections could be assigned

Please review the web page...

View Article


RE: RAM Concept Balance Loading

To define tendons for the new balanced load percentage, you would either need to manually edit the tendon and change the number of Strands per Tendon or start a new model. The Balanced Load Percentage...

View Article

RE: Ram Elements Single Angle AISC 360-10

Local member deflections are associated with the principal axis. The exception is when the "Laterally Restrained for Torsion" option is checked for use in the section properties. In that case, the...

View Article

Ram Elements Single Angle AISC 360-10

Does Ram Elements properly apply the AISC 360-10 single angle requirements for bending, compression and combined stress for equal and unequal leg single angles?Is deflection given for the geometric or...

View Article


Image may be NSFW.
Clik here to view.

Base plate design using RAM connection

This is regarding RAM connection software. The module we have does not show base plate and foundation bolt design (see 2nd pic). As per the tutorial we are supposed to have that package.(See 1st...

View Article

RE: Plate Element Unity code check

Unity ratio is reported if the steel section is selected directly from the Standard Steel section database or it is created as I shaped section generated by the CREATE USER TABLE. The standard steel...

View Article

Plate Element Unity code check

Good morning STAAD Community,I am modeling a W6x20 which will be suspended by a 1.5" diameter bar from the top flange and will be supporting a 24" diameter pipe with 2-Ubolts. I am trying to get the...

View Article


RE: STAAD buckling analysis

Sorry, the server issue is not fixed yet. I'm still working with Mr. Palaniappan.

View Article


RE: SELX/SELY Concrete Wall Russian Code SNiP 2.03.01-84*

hi all! additional questions: 1. please, could you state the number of items or formula in Russian SNiP, where above two parameters are used/have influence? separate for wall, separate for slab design....

View Article

Image may be NSFW.
Clik here to view.

SELX/SELY Concrete Wall Russian Code SNiP 2.03.01-84*

Hi all!Could you please, clarify about above design parameter. For example, height of concrete wall is 3m and its divided into 6 parts (each 0.5m), so for each part SELY shall be 3m or 0.5m?Happy New...

View Article

RE: Columns getting failed.

sir this is the model which is getting failed, if we decrease the depth of web of center column( R3 property) from 250 mm to 200m it will get passed. STAAD SPACE START JOB INFORMATION ENGINEER DATE...

View Article

Columns getting failed.

i am attaching my staad file, please anybody tell me why the columns in the middle, gets failed when i increase the size of column web, but when i decrease the size it shows the result as passed.kindly...

View Article


Image may be NSFW.
Clik here to view.

RE: load carrying capacity of compression member by using 4 ISA built up...

Hello Rohit,You can use "Star Angle Arrangement" option and assign the same section property to respective member, STAAD.Pro can design "star angle" sections as per IS 800 and from design output you...

View Article

RE: load carrying capacity of compression member by using 4 ISA built up...

Please refer to the following section of Technical Reference manual: AD.2007-09.3.4 Star Angle Design per IS-800 It talks about the design of "star" angle arrangements per IS 800:2007 .

View Article


RE: Design of industrial shed on concrete column.

Can you please send us the sketch of full arrangement?

View Article

RE: RC Designer Staad.Pro

Please also upload .std file.

View Article


Image may be NSFW.
Clik here to view.

RE: load carrying capacity of compression member by using 4 ISA built up...

You can go through the "Technical Reference manual" of STAAD.Pro (Help >> Contents).

View Article

Image may be NSFW.
Clik here to view.

RE: Design of industrial shed on concrete column.

View Article

RE: RC Designer Staad.Pro

In order to investigate this issue, please provide the following information:· Please attach/upload the .std and .rei_concrete file· Product Version number(s), for example: STAAD.Pro version xx.xx.xx.xx