Backup section database after updating the staad connect edition.
Hi,I want to update the staad to update 4 but before doing so, I would like to retain the section database library that I have created. I have added numerous sections and every time I update, the...
View ArticleProduct - Deep beam design
Hi,Just wondering do you have any product that can design a deep beam for :-1. Australian code - AS36002. If not AS3600, then what about other codes? Thank you!
View ArticleRAM SS - ISM - benefits
Hi,Just wondering what are the benefits of using ISM on RAM SS?Does it just exported the model to Revit? or it can do more stuff?I would like to know how does it help in our design and documentation...
View ArticleRAM SS - change wall properties method
Hi,For example, if I have 15 types of layout with walls, and I would like to change the concrete grade of all the walls, are there any way of changing them using Fence in 3D?
View ArticlePostgreSql database restoration
 password for postgreSQL is not taking correct one for rcdc softwareÂ
View ArticleMaterial Take Off
Getting the weight of material from Steel Auto Drafter which not match practicallywould you pls advice what the reason
View ArticleRAM Concept - design strip for mild reinf transfer beam in pt slab
I have a mild reinf transfer beam in line with a banded tendon group in a pt slab. The transfer beam is designed for all loads (column load above and adjacent slab tributary loads). The PT band will...
View ArticleRAM Concept - opening in pt slab design strip
I have an opening in a pt slab design strip. Can the strip wrap around the opening as shown or should I provide a span boundary polyline along the left side of the opening? Thank-you.
View ArticleAxial force developed in main beam due to assignment of offset
Consider a simply supported beam. Apply a uniform distributed load. You will get shear and bending, but no axial force.Next, apply a local Y offset (or a global Y offset) at both ends. Apply the same...
View ArticleRCDC - Load combinations "Add from analysis" error
Hi everyone,Regarding RCDC, I am having some problems importing load combinations from analysis file. In STAAD I have my primary loads and my loads combinations. After analysis I move to RCDC and model...
View ArticleDesign Contradicting Results
Hello,When I run the design, some member shows contradicting forces results. For example, when I double click on a member, I find the compression force capacity is shown as 135.3 kips, while in the...
View ArticleRAM Concept - Mat Foundation Sliding and Overturning
Bentley Team,I am currently designing a 9-story residential building with a mat foundation. We are trying to determine at what depth is the mat foundation required to be based on sliding and...
View Article*warning* actual weight of structure zero for self weight.
Hi,I am getting the following error, however it is not immediately obvious to me why.*warning* actual weight of structure zero for self weight.Can anyone clarify what this means?Thanks.
View ArticleInclined floor - Floor load
Hello,I am struggling to define floor load to the top of the roof in the structure attached. I keep getting Y range issues. Can someone please help me with that.I even tried assigning a group to the...
View ArticlePlate Material Take Off
Dear AllHow do get Material Take OFF for Plate formed Elements like Duct & Steel Tank of various Thickness in STAAD Pro Connect Edition.RegardsChenthil
View ArticleSTAAD WARNING- NO MEMBERS LOADED FOR A FLOOR LOAD GENERATION.
Please help :(((1. STAAD SPACE 2. START JOB INFORMATION 3. ENGINEER DATE 4. END JOB INFORMATION 5. INPUT WIDTH 79 6. UNIT METER KN 7. JOINT COORDINATES 8. 1 0 1 0; 2 1.8 1 0; 3 0 1 1.1; 4 1.8 1 1.1; 5...
View ArticleHow to find out which part of the structure is disjointed?
HeyI have got the warning that this structure is disjointed, as well as the error for calculating natural frequency.Could you help me to fix the problems? I have uploaded the std file in...
View ArticleStaad Tekla direct link
Hello! What is the latest version of Tekla (and also for Staad) where the direct link is working properly? Thank you in advance.BR,Gabor
View ArticleV8i to connect edition
Hi,I had created a file around three years back in V8i select series.Now I am able to open the file in connect edition but it does not provide me the results.How can I run the analysis and extract the...
View Article