RE: STAAD Foundation
Erika: The STAAD.Pro Advanced Analysis license does NOT include STAAD Foundation Advanced (SFA). To use SFA, you will need to have a separate license for the product. The current version of STAAD.Pro...
View ArticleSTAAD Foundation
Hello, If you own a licence of the Advanced Analysis processor in STAAD Pro V8i, do you automatically have access to STAAD Foundation? If so, how do I make sure I am using the most current version of...
View ArticleURGENT!!!! INSTABLE JOINTS
URGENT!!!Please help me with this warning!See attached staad file[View:/cfs-file/__key/communityserver-discussions-components-files/5932/6x6shelter17.std:940:0] ***NOTE - VERY WEAK SPRING ADDED FOR...
View ArticleRE: STAAD Error on design of beam with cover plate
The design if I sections with cover plates was not available in STAAD.Pro build 20.07.11.33. Please upgrade to the latest STAAD.Pro version (20.07.11.82) where this design will be performed.
View ArticleRE: ***WARNING - INSTABILITY AT JOINT 234 DIRECTION = FZ
There are a lot of members in your model which are not intersecting, so this leads to instabilities. To fix that, select all the members in the model and go to Geometry -> Intersect Selected Members...
View ArticleRE: STAAD Error on design of beam with cover plate
It seems your primary concern is failing of the member in code checking. I have checked with SS6 - Build Number 20.07.11.82 and it is failing there too with a ratio of 1.767. This is not an error in...
View ArticleSTAAD Error on design of beam with cover plate
Hi,I am getting error in designing beam with cover plate. [View:/cfs-file/__key/communityserver-discussions-components-files/5932/9m.std:940:0]I am using (SS6 20.07.11.33).
View ArticleRE: Envelope types
Envelope Type (like STRESS, STRENGTH, SERVICEABILITY etc.) are optional key words to specify qualitative nature of the load or load combination cases included in the envelop definition. Based on the...
View ArticleRE: Envelope types
Thanks for your reply I've gone through the technical manual but I couldn't find any definition for the STRESS or STRENGTH envelopes. The SERVICEABILITY and COLUMN envelopes are a little bit clear but...
View ArticleRE: Buckling mode shapes
The mode shapes can be seen graphically only when the buckling analysis is performed using the Advanced Analysis Engine. The mode shapes can be found in the Postprocessing mode, Buckling vertical page.
View ArticleBuckling mode shapes
Hi,After completion of buckling analysis, how can I see graphically buckling mode shapes?Regards,
View ArticleRE: Advanced cable analysis for cables with member offset command
Use of Member Offsets are not allowed for Cable members in STAAD.Pro. For more details, please refer to the Notes mentioned under Section 1.18.2.8 - Advanced Non-Linear Cable Analysis, of Technical...
View ArticleAdvanced cable analysis for cables with member offset command
Hello Everyone,I have a model where the cable is not extended to the centroid of the Beam (CHS). I have offsetted the cables by 680mm in the local longitudinal axis as per the following detail:-....
View ArticleRE: Envelope types
STRESS is mainly targeted for Load Envelope created for Allowable Stress based design and STRENGTH is mainly for Load Envelope created for Capacity based design. However, these names are tags only and...
View ArticleEnvelope types
HiCan any one tell me what is the difference between STRESS and STRENGTH envelope type?
View ArticleRE: ***WARNING - INSTABILITY AT JOINT 234 DIRECTION = FZ
Thank you that help me out alot.
View Article***WARNING - INSTABILITY AT JOINT 234 DIRECTION = FZ
Hello, I was wondering if any can help me with my STAAD model.I have all the nodes and beams in, I have release the joints that need to be release. I am having troubles with instability at joints and I...
View ArticleRE: RAM Concept - Corrupted File
Once a file get's like this it can't be fixed. You can try restoring the backup files (.bak1 or .bak2), but depending how many times it was saved those may also be corrupt. We did correct the...
View Article