Quantcast
Channel: RAM | STAAD Forum - Recent Threads
Browsing all 23543 articles
Browse latest View live

RE: Specifying STAAD design code using VBA macro

That example won't run as written (as you found out). You have to instantiate the OpenSTAAD library first. Look in the OpenSTAAD help under "Fundamentals of OpenSTAAD -- Instantiating the OpenSTAAD...

View Article


RE: DENSITY NOT PROVIDED. SELFWEIGHT COMMAND IGNORED.

No need to start from scratch. The problem is that Michael has defined the material concrete but the material has not been assigned to the members as Modestas has correctly pointed out. If he adds the...

View Article


RE: How do I remove the beams numbers (R2)...?

What Modestas mentioned is correct. However for certain situations, you may need to follow the steps outlined in the wiki below communities.bentley.com/.../32441.turning-off-labels

View Article

RE: file conversion of .std file to .stp file which can be exported to...

The only way to go from SolidWorks to STAAD that I know of is via ISM and using an ISM Translator available from SolidAce (www.solidace.com),  http://youtu.be/NOGKmJCedXw . But if you are trying to...

View Article

file conversion of .std file to .stp file which can be exported to Solidworks...

I have been  searching for a solution to convert my STAADpro  file to STEP file which i can open in solidworks. The converted .stp format that we export from Staad is CIS/2 which cannot be read by...

View Article


RE: staad pro v8i series 6 student user license

If you still need help with this issue, please go through the link below to activate STAAD.Pro.communities.bentley.com/.../4482.how-do-i-activate-my-bentley-software

View Article

staad pro v8i series 6 student user license

I installed the staad pro software from my student portal using the university id, and now a few days later after installation the program does not allow me to create or open files.  A colleague of...

View Article

RE: Specifying STAAD design code using VBA macro

Your right, it's hard to find resources about OpenStaad and we have no choice but to try every example on the reference provided by Bentley. Anyways, I did what you suggested and I managed to run the...

View Article


RE: What is the difference between the Load combination and load envelops ?

Load Combination combines one of more primary load cases with certain combination factors whereas a Load Envelope is basically a group of load cases/combinations. The Load envelopes can be used for...

View Article


What is the difference between the Load combination and load envelops ?

What is the difference between the Load combination and load envelops ? and why does the bending and shear diagrams are calculated only for one load case and not for the combinations . I am...

View Article

RE: Creating Composite Deck & its Properties

You do NOT need to define composite decks one by one. If the deck properties and the direction are same, you can define a single deck covering all the members. Just identify the boundary of the deck by...

View Article

Image may be NSFW.
Clik here to view.

Creating Composite Deck & its Properties

Hello,1. Anyone knows how to apply the same composite deck properties to all deck without doing it one by one? I'm using STAAD.Pro 2006?2. In STAAD.Pro, do I need to create 1 composite deck between...

View Article

RE: STAAD DESIGN OVERHEAD TRANSMISSION TOWER ASCE 10-97

Thank you! Kris! Looking forward to your reply! Thank you!

View Article


RE: Staad foundation Advance Error

thanks for your reply it helps me...

View Article

Image may be NSFW.
Clik here to view.

Staad foundation Advance Error

hi, Every time I have to open my installed Staad Foundation Advance it shows an error,  here it is how can I solve this,,,, thanks

View Article


Is it possible to turn WARNING off in STAAD output

Hi,Is it possible to turn WARNING off in STAAD output? I have surface elements side by side with each other and I'm getting WARNING below. I know the WARNING does not affect the result or the analysis...

View Article

RE: STAAD: Load combination name getting truncated

You may try reducing the font size, however, if the name is very long, it probably will not fit either. I am not sure if there is any other way to see the full combination name in this table.

View Article


STAAD: Load combination name getting truncated

Hi,When printing load combinations using Report option the load combination name gets truncated (see attached). Is there a way to show the full load combination...

View Article

RE: ISM Connection between RAM Structural System and STAAD PRo

We are in the process of enhancing STAAD.pro ISM link to support plates (surface members in ISM). Right now it only imports linear members, (beams and columns basically). What feature are you looking...

View Article

ISM Connection between RAM Structural System and STAAD PRo

Can RSS models with concrete walls and slabs only be transferred to STAAD PRO using ISM?  The intent is to build the geometry in RSS and then transfer the geometry to STAAD Pro using the ISM...

View Article
Browsing all 23543 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>