RE: RAM steel beam takeoff query
Can you please upload your model and cite us where it is including those sections?
View ArticleRE: RAM steel beam takeoff query
Model has been uploaded thanks. See below for beams exceeding depth restriction but included in takeoff.ThanksAllan
View ArticleRE: RAM steel beam takeoff query
Beam depth restrictions work like this. If the user assigns a depth restriction that is too limiting and no beam within the depth restriction works, then the program provides a warning in the Design...
View ArticleRE: What is the problem in my model?
You have not added PERFORM ANALYSIS command. You need to add that.There are warning for wind load generation. There are few instances where the WIND load command is not associated with a specific...
View ArticleRE: Staad Foundation Advanced
Just ran into this post. The answer is posted at communities.bentley.com/.../30352.what-are-analysis-thickness-and-design-thickness-in-sfa
View ArticleStaad Foundation Advanced
I'm using Staad Foundation to design a mat foundation and there are high moments at the location of the column.Is there a way to exclude the area near the column for the reinforcement check since the...
View ArticleRE: Wind load on SP 20.13330.2011
Can you please share your model and if possible also mention your expected load value.
View ArticleWind load on SP 20.13330.2011
I’m a Civil Engineer employee of Technip and I would kindly request support and clarification about the application of wind loads based on the SP 20.13330.2011. The main concerns is about the...
View ArticleRE: What is the problem in my model?
For the warning messages, you can avert them by using the group option .If you see the load/Case 6 , then few of the wind loads falls on the projected area of the inclined panel.Wind load will not be...
View ArticleWhat is the problem in my model?
after putting the loads, I analyzed my model and found 2 errors and three warnings? what does this errors mean? i cannot continue my work because of these...
View ArticleRE: What load shall I used? (Seismic Definition)
Yes. It will be 100% of DL and 25 to 50% of LL depending on LL intensity.
View ArticleWhat load shall I used? (Seismic Definition)
in the seismic defnition UBC 1997, under Element Weights or Floor Weights, what weight shall I used here, is it the Dead Load or Live Load?
View ArticleRE: RAM Concrete beam not being loaded by slab
If part of the floor slab at that level is two-way, then the whole thing gets meshed and that could cause the behavior you describe. More on two-way slabs here:
View ArticleRE: RAM Concrete beam not being loaded by slab
Seth, I certainly appreciate the reply. Yes, this model has a two-way slab at one point in the building. This beam is located under a section of one-way slab that is some distance away. The loads being...
View ArticleRE: RAM Concrete beam not being loaded by slab
The only way to completely avoid having the slabs meshed is to use only one-way slabs on that level (other levels could still be 2-way). A visual confirmation of the meshed finite element model is...