RE: how to add check storey drift command in response spectrum analysis for...
I couldn't find out that check storey drift command in staad. There is storey drift command in post print option in analysis section.
View ArticleRE: how to add check storey drift command in response spectrum analysis for...
You need to use this command from STAAD editor.
View Articlehow to add check storey drift command in response spectrum analysis for...
how to add check storey drift command in response spectrum analysis for calculating displacement in x and z dircection
View ArticleBolted End Splice with Compressive axial load
I am trying to design a Bolted Beam Splice W10X49 & 1" End plates using the BS with Flush Plates.I have Compression axial load and weld on flange is not good because it does not develop the...
View ArticleRE: Canadian code Beam Length Design Error
Beams (518-530-542-559-579) and Beam 553 have the same span and are under the same load conditions so they should have the same MZ value in their mid span but calculated MZ for Beams...
View ArticleRE: Canadian code Beam Length Design Error
Though the beams (518-530-542-559-579) and beam 553 have the same span and are under the same load conditions, but the former set is laterally restrained at intermediate points, where as beam 553 is...
View ArticleRE: MATRIX BANDWIDTH PROBLEM
I tried with the advanced analysis also, it shows MFC application has stopped working error. This error i reported already during my previous post
View ArticleMATRIX BANDWIDTH PROBLEM
Hi,I have some problem in my STAAD model, "matrix bandwidth error" is coming. I don't know clearly whether the problem is due to the internal memory of my computer configuration or due to my STAAD...
View ArticleRE: Cable Mullion System in STAAD
What is the difference between pretension load in cable member specification and in the load cases (member load -> Pre/Post Stress) The other thing is that I have problem with checking the...
View ArticleRE: Cable Mullion System in STAAD
The tension specified in the cable member is applied on the structure as an external load as well as is used to modify the stiffness of the member. Please refer section 5.23.2 of the Technical...
View ArticleRE: Cable Mullion System in STAAD
Hereby, I attach the files of my cable analysis, maybe you can have further explanation of what happenThanks(Please visit the site to view this file)
View ArticleRE: Cable Mullion System in STAAD
Please refer the updated input file uploaded here for knowing the displacements related issue.(Please visit the site to view this file)
View ArticleRE: ERROR-OUT-OF-BALANCE LOADS LARGER THAN INCREMENTAL LOADS AFTER ITERATION...
This issue is addressed in the following Bentley Communities Link - Cable Mullion System in STAADcommunities.bentley.com/.../119317
View Articlevariable cross section combined profile
Hi, I would like to add a variable cross section combined profile to my model. This column is combined from a HE180A with a diagonal cut IPE profile on it. So, a HE180 beam with varying T section on...
View ArticleRE: Cable Mullion System in STAAD
Thank you for the correction, but I found another problem that the deflection occurs in Y axis. Actually, it has to be at the Z-axis (horizontal deflection) I find that the temperature has only be...
View ArticleOpenstaad creating listbox using vba.
While creating listbox for example , for adding load envelope, is it possible to have multiple selection and adding to the selected listbox, in vba.
View ArticleRE: Cable Mullion System in STAAD
I would suggest to use advanced cable analysis feature available with advanced solver. You need to use REPEAT LOAD command to combine the primary load cases instead of load combinations. Please refer...
View ArticleRE: Bolted End Splice with Compressive axial load
Hi Mike, can you please attach your RAM Connection file with this joint detail. Please also confirm what version of RAM Connection you are using?
View ArticleRE: ERROR-OUT-OF-BALANCE LOADS LARGER THAN INCREMENTAL LOADS AFTER ITERATION...
Please refer to the modified model attached herewith.(Please visit the site to view this file)
View ArticleERROR-OUT-OF-BALANCE LOADS LARGER THAN INCREMENTAL LOADS AFTER ITERATION 153...
Hi guys,I have a problem with this kind of error in cable analysis. Please help me to fix this error. Some advise or suggestion. Any reference for cable analysis would a good help.Hereby, I attach the...