RE: STAAD Pro - Reference loads and repeat loads
Also please refer the Section 5.31.6 - "Defining Reference Load Types" of the Technical Reference Manual. It also has those clarifications.
View ArticleDesign of Columns in Tension per Eurocode
HiCurrently staad does not design columns in tension for both the BS and European codes using the RC Designer. Is there any procedure available in some text book that can be followed considering that...
View ArticleRE: Warnings: **WARNING: IF THIS UBC/IBC ANALYSIS HAS TENSION/COMPRESSION OR...
When you provide a seismic definition, the program computes horizontal base shear. This base shear is distributed among different stories as storey shears. This storey shears are the applied seismic...
View ArticleRE: Warnings: **WARNING: IF THIS UBC/IBC ANALYSIS HAS TENSION/COMPRESSION OR...
An explanation about the seismic load warning can be found here: communities.bentley.com/.../23990 An explanation about the selfweight warning can be found here: communities.bentley.com/.../23990
View ArticleWarnings: **WARNING: IF THIS UBC/IBC ANALYSIS HAS TENSION/COMPRESSION OR...
Please help.. I am having warning messages.. Can this affect the result or should I neglect the warnings? Thank you very...
View ArticleRE: Analysis of Foundations Subjected to Dynamic Loads
You can create a node where you apply the load. This node need to have a rigid master/slave connection with the other nodes where the load has to be transferred.
View ArticleRE: STAAD Pro - Reference loads and repeat loads
Please refer to the attached sample model. I hope this helps.(Please visit the site to view this file)
View ArticleSTAAD Pro - Reference loads and repeat loads
Hi, I have a model in STAAD.Pro V8i Select Series 2, with 50 primary load cases, 10 of which are acting as combinations using the REPEAT LOAD command.The model has many plates and compression/tension...
View ArticleRE: Multiple Analyses (construction sequence)
Can you please attach the STAAD.Pro model?
View ArticleMultiple Analyses (construction sequence)
Hello there,I am trying to analyse a structure which is incrementally subjected to dead loads using the inactive members / change commands so I can simulate the sequence of construction. There are...
View ArticleRE: Hi Everyone, I am modeling a Vierendeel truss pedestrian bridge. I am...
Hi Sharath, Few observations on your model - 1. The model has few instabilities and in order to remove that I have made few changes in the support specification. Support spec - "122 222 FIXED BUT FX FZ...
View ArticleRE: Skewed Railroad Through Girder
Hi, You mentioned that - "The maximum moment in the girders is coming out very low." What is the maximum value you are getting, and for which member and what is the corresponding load case number? Can...
View ArticleRE: Skewed Railroad Through Girder
The maximum moment is 4941.67k-ft in beam 209 at load case 148. I am expecting the maximum moment to be about 5343k-ft.
View ArticleSkewed Railroad Through Girder
I have a 106'-3" skewed through girder rail road bridge, the skew is very large about 55 deg. I created a 3D model and run the moving train load across the bridge. The maximum moment in the girders...
View ArticleRE: Minimum Size Requirements for Composite action
In Ram Structural System? If so you can assign various dimension controls in Ram Modeler - Layout - Beam - Size restrictions (like minimum flange width) if that's the key factor. Otherwise you can edit...
View ArticleRE: Contrasting Results
Are the deflections under notional loads also excessive? it's probably best to send over your input file (as an attachment using advanced Reply Editor option).
View ArticleRE: Minimum Size Requirements for Composite action
Yes. I didn't realize that the difference was the flange width of at least 4.01 so thank you! I was trying to specify depth restrictions. Didn't realize there was a flange width restriction too! Thank...
View ArticleMinimum Size Requirements for Composite action
I have been instructed that the minimum 8x 10x and 12x for composite action are 8x15, 10x17, and 12x19. Is there a way to include these design restrictions in the program? I have tried a min depth size...
View ArticleRE: Hi Everyone, I am modeling a Vierendeel truss pedestrian bridge. I am...
Thank you so much Amitava. I made those corrections, and its still like 3ft deflection which is more than serviceable criteria for the pedestrian bridge. I am strictly suggested not to use bracings and...
View ArticleHi Everyone, I am modeling a Vierendeel truss pedestrian bridge. I am getting...
STAAD SPACESTART JOB INFORMATIONENGINEER DATE 08-Dec-15END JOB INFORMATIONINPUT WIDTH 79*UNIT FEET KIP*JOINT COORDINATES*TRUSS 1 BOTTOM CHORD101 0.0 0.0 0.0 122 126.0 0.0 0.0 1* TRUSS 1 TOP CHORD123...