Deflection Check using AISC-2010 and a Serviceability Envelope

$
0
0

Good day,

Is there a way to have STAAD check two different deflection checks for two different load envelopes?  

I tried to create two serviceability envelopes and assign to two different parameters. see below. I also tried other ways but nothing worked for me. Looks like STAAD can only perform a single deflection check? Thanks. 

DEFINE ENVELOPE
1 ENVELOPE 1 TYPE SERVICEABILITY
2 ENVELOPE 2 TYPE SERVICEABILITY
END DEFINE ENVELOPE
LOAD LIST ENVELOPE 1
PARAMETER 1
CODE AISC UNIFIED 2010
UNT 1500 MEMB 10 TO 16 25 TO 31 39 40
UNT 1550 MEMB 1 TO 8 17 TO 23
LX 1500 MEMB 10 TO 16 25 TO 31 39 40
LX 1550 MEMB 1 TO 8 17 TO 23
DFF 340 ALL
DJ1 1 MEMB 1 TO 8
DJ2 10 MEMB 1 TO 8
DJ1 11 MEMB 10 TO 16 40
DJ2 18 MEMB 10 TO 16 40
DJ1 19 MEMB 17 TO 23
DJ2 27 MEMB 17 TO 23
DJ1 27 MEMB 25 TO 31 39
DJ2 35 MEMB 25 TO 31 39
FU 0.448159 ALL
FYLD 0.344738 ALL
METHOD ASD
CHECK CODE ALL


LOAD LIST ENVELOPE 2

PARAMETER 2
CODE AISC UNIFIED 2010
UNT 1500 MEMB 10 TO 16 25 TO 31 39 40
UNT 1550 MEMB 1 TO 8 17 TO 23
LX 1500 MEMB 10 TO 16 25 TO 31 39 40
LX 1550 MEMB 1 TO 8 17 TO 23
DFF 220 ALL
DJ1 1 MEMB 1 TO 8
DJ2 10 MEMB 1 TO 8
DJ1 11 MEMB 10 TO 16 40
DJ2 18 MEMB 10 TO 16 40
DJ1 19 MEMB 17 TO 23
DJ2 27 MEMB 17 TO 23
DJ1 27 MEMB 25 TO 31 39
DJ2 35 MEMB 25 TO 31 39
FU 0.448159 ALL
FYLD 0.344738 ALL
METHOD ASD
CHECK CODE ALL
FINISH