Hi Provas,
There is no such restrictions for Master node location. According to your requirement you can specialize a node as Master node.
But, you need to maintain the following points while assigning Master/Slave Specification:-
- Solid elements may not be connected to slave joints.
- Master joints may not be master or slaves in another entry.
- Slave joints may not be master or slaves in another entry.
- Slave directions at joints may not be supported directions or have displacements imposed.
- Master and/or slave joints may not be inclined supports.
- The master / slave specification is only intended for linear static and dynamic analysis.
- Multi linear springs are not permitted.
You can also go through STAAD.Pro Technical Reference Manual (5.28.1) for more details.
Hope this helps you.
Thanks.