RE: *** WARNING *** DYNAMIC MASSES IN GLOBAL X, Y AND Z DIRECTIONS ARE NOT SAME. WARNING MESSAGES ARE WRITTEN IN _MASSEURO.TXT FILE.

$
0
0
Thank you for your quick reply.
Regarding vertical standing members, i will modify them.
Eurocode don't specify any limit of mass participation, this 60% was just for indicating a limit of result obtained for particular mode.
What was my conception before this, any particular mode should contribute close to 90% of mass,
So do you mean it is not so?
Also for Y direction it has hardly crossed 5% mass, is it still ok?
For base shear in Z direction it is showing 0 even for 5th mode which has 51% mass participation in Z dirn.
But ideally there must be some value , don't you think so?