The central columns are failing because you have an unsupported length of 13m. You need to increase the ry ( radius of gyration wrt. minor axis) for these members as slenderness about the minor axis is the one governing. Parameters that would directly influence this slenderness are LY, KY ( design parameters ) and ry ( section property).
↧